| Dimensions |
1172 mm× 1026 mm × 2 mm |
| Connection specification |
MC4-compatible |
| Weight (kg) |
3.2 kg |
| Maximum power – Pmax (W) |
200 ± 5% |
| Voltage at Pmax (Vmp) |
34,71 |
| Current at Pmax – Imp (A) |
5,93 |
| Open-circuit voltage (V) |
41.64 ± 5% |
| Short-circuit current – Isc (A) |
6.22 ± 5% |
| Module efficiency – ηₘ (%) |
16:09:00 |
| Power tolerance (W) |
(0, +5) |
| Maximum system voltage (VDC) |
1500 (IEC) |
| Maximum series fuse rating (A) |
25 |
| Output cable |
3m lang, 4,0 mm2, 450 mm (+), 450 mm (-) |
| Pmax temperature coefficient (%/°C) |
−0.34%/℃ |
| Voc temperature coefficient (%/°C) |
−0.26%/℃ |
| Operating temperature (°C) |
–40 °C to +85 °C |
| Nominal module operating temperature (NMOT) (°C) |
41 ± 2 °C |
| Scope of delivery |
1. 200 W flexible solar panel × 4
2. User manual × 1
3. MC4 Y-splitter solar cable (× 3 pairs) × 1
4. Rope × 8
5. Rope tensioner × 8
6. Rope clamp × 8
7. Stainless steel cable tie × 8 |
| Is the product sold? |
Yes |
| Warranty |
12 years |
| IP rating of the terminal box |
IP68 |
| Is the solar panel supplied with a mounting structure? |
No |
| Rated power (STC) |
200 W |
| Cell type |
Monocrystalline silicon (182 mm half-cell) |
| Frame color |
Schwarz (Full Black) |
| Are additional components required? |
no |
| Is professional installation required? |
no |
| Is a Y-cable included in the delivery? |
yes |
| Main application scenarios |
This solar panel is primarily designed to power Solar energy storage systems, and is particularly suitable for the following scenarios:
Balcony or Outdoor Installation: The panel can be mounted on balcony railings using the included mounting accessories to generate electricity from sunlight.
Compatible with the following devices:
Jackery Navi 2000
Jackery HomePower 2000 Ultra
Jackery SolarVault 3 series
Parallel Connection Configuration:
A single MPPT tracker on the battery supports the parallel connection of 2 or 4 solar panels.
Series connection is generally not recommended, as it may exceed the input voltage limit (the open-circuit voltage of the batteries is typically within 60V).
When connecting 4 panels in parallel, it is advisable to first connect them in pairs (2+2) using Y-connectors, and then combine both pairs into one MPPT input.
Connection Method: Parallel connection is achieved using MC4 Y-branch cables to link the panels to the PV input ports of the battery.
Lightweight and Space-Saving Design: Thanks to its flexible, lightweight construction (only 2 mm thick and weighing 3.2 kg), it is ideal for installations on surfaces with limited load-bearing capacity.
Other Installation Options: The panel can also be mounted on surfaces such as RVs or walls, which are often enclosed on one side. For such installations, you may need to purchase suitable mounting materials separately, such as industrial adhesives, brackets, or locking mechanisms. |
| Installation method (differentiated by application scenarios) |
BALCONY RAILING INSTALLATION GUIDE
Mounting Accessories:
Rope ×2
Rope tensioner ×2
Rope clamp ×2
Stainless steel cable tie ×2
Installation Steps:
Step 1: Prepare the ropes
Install a rope clamp 20–30 cm from the end of the rope.
Thread the rope through the eyelet buckle on the solar panel.
Thread one end of the rope into the tensioner.
Step 2: Secure the upper ends
Pass the upper end of the rope over the railing beam.
Thread it through the other inlet port of the tensioner.
Turn the solar panel over the railing to position it outside the balcony.
Step 3: Secure the lower ends
Wrap the lower end of the rope around the railing beam.
Thread it through the rope clamp and tighten.
Pull the upper end of the rope to ensure the panel is securely fastened.
Step 4: Reinforce the middle section
Use stainless steel cable ties to secure the solar panel to the railing beam through the middle mounting holes.
Ensure the tails of the cable ties face inward to prevent injury.
IMPORTANT NOTES
Do not bend, step on, disassemble, or drop the solar panel.
Avoid placing the panel in shaded areas or immersing it in water.
When connecting cables, ensure correct polarity (positive/negative) to prevent reverse connection.
During installation, do not loosen both rope clamps at the same time to prevent the panel from slipping. |